Bablo ResourcesDocs

Cabinet Repair

The large distribution cabinet (Large breaker box in the Route Creator) is repaired with a breaker puzzle. It has twelve numbered breakers, a red MAIN switch and a panel monitor.

In short: switch the power off, find the right switch order with the help of the monitor, then switch the power back on to test it. A cabinet takes 4 or 5 rounds of this.


Starting a repair

Walk up to a cabinet on your crew’s route and choose Open service cabinet. Without a target script you press E at the prompt instead.

RuleDetail
RouteThe cabinet must be on your crew’s active work order and not restored yet. The crew must have collected the van first: Collect your work van first.
VanThe crew van must be within 150 metres: Park your crew van near the work site. See Work Van.
DistanceYou must stand within Config.Job.repairDistance (3 metres): Move closer to the cabinet.
One technicianOnly one player works a cabinet: A technician is already working here. A crewmate can help, see Helping a Crewmate.
Not while helpingStop assisting before opening another cabinet.

Your character walks to the cabinet first. If something is in the way, you get Move into clear space in front of the cabinet, then try again.

The character then opens the cabinet door, seen from a camera behind you. This takes Config.Job.openMs (3 seconds). Players nearby see the door open as well. After that the camera moves close to the panel.


Controls

KeyAction
MouseMove the cursor. A control you can use gets an outline when you point at it, and the cursor turns into a hand.
LMBFlip the breaker or the MAIN switch under the cursor.
ScrollZoom in towards the cursor, up to four times. Scroll back to zoom out.
RMBReset the view.
EscLeave the repair. Progress on this cabinet is lost.

The HUD and minimap are hidden during the repair. Your own character, and anyone standing right at the cabinet, are hidden from your view so they don’t block the panel. Other players still see everyone.


The panel

  • Breakers: twelve switches numbered 01 to 12, in three rows of four, counted left to right from the top row. Each has a pair of lamps above it. The green lamp lights when the breaker is latched in the right order, otherwise the red one is lit.
  • MAIN: the red power switch at the top right.
  • Panel monitor: the screen at the top left.

Panel monitor

PartWhat it shows
HeaderPANEL MONITOR and the supply: SUPPLY ON or SUPPLY OFF.
BREAKERThe number of the breaker under your cursor, while MAIN is off.
Contact readingWhat that breaker is: ENTRY CONTACT, CONTACT, NO CONTACT or LATCHED. See Find the switch order.
CONTACTSOne cell for each switch in this round’s order (4 to 6). A cell fills for each switch you latch, with a count such as 02 / 05.
Message lineThe result of your last action, or an error. Errors stay for a few seconds.
FooterThe cabinet state (INTERLOCK while the power is on, ISOLATED while it is off, CHECKING during the test, ONLINE when restored, FAULT after a shock), the round (ROUND 02 / 05) and RESETS 01, the number of mistakes during this repair.

Everyone within 18 metres sees the monitor while a repair runs. The BREAKER number and the contact reading are only shown to the technician who is working the panel.


Repair steps

1. Switch off the power

At the start of each round MAIN is on and all twelve breakers are off. The monitor reads SUPPLY LIVE. The breakers can’t be used while the power is on: SWITCH MAIN OFF FIRST.

Click MAIN. The monitor reads SUPPLY ISOLATED.

2. Find the switch order

Each round has a hidden order of 4 to 6 of the twelve breakers. Point at a breaker and read the monitor:

ReadingMeaning
ENTRY CONTACTThe first switch of the order.
CONTACTPart of the order, but later. The monitor does not say at which position.
NO CONTACTNot part of the order. Leave it off.
LATCHEDAlready switched on in the right order.

Click the switches in the right order, starting with the entry contact:

You clickResult
The next switch of the orderIt latches and its green lamp lights: CONTACT LATCHED. After the last one: INTERLOCK SET.
A switch of the order out of turn, also one that is already latchedINTERLOCK TRIPPING. A moment later every breaker drops and the round starts again from the first switch: INTERLOCK RESET. The panel is locked until then.
A NO CONTACT switchAll latched switches drop: NO CONTACT / INTERLOCK RESET. The switch you clicked stays on. Switching it off again costs nothing: CONTACT OPEN.

Each wrong click is a mistake and adds one to RESETS. After a reset the order stays the same for the rest of the round, so remember what worked.

3. Test

When the monitor shows INTERLOCK SET, click MAIN to switch the power back on: CHECKING SUPPLY. The monitor shows SUPPLY SCAN and VERIFYING SUPPLY while relays click for Config.Job.verifyMs (2.2 seconds).

Clicking MAIN before the order is complete does nothing except INTERLOCK OPEN.

4. Next round, or close up

If rounds are left, the next one starts right after the test: MAIN is on again, the breakers are off and the order is new, with an entry contact you have not had before in this repair. The monitor reads NEXT CIRCUIT BANK. Start again from step 1.

After the last round the camera pulls back and your character closes the door, which takes Config.Job.closeMs (3 seconds). The monitor reads SUPPLY RESTORED.


Rounds

A cabinet has 4 or 5 rounds, picked at random when you open it. Every round has its own order of 4 to 6 switches. The monitor shows the round you are on, for example ROUND 03 / 05.

With Config.DEBUG = true every cabinet has a single round. Use it for testing only.


Mistakes and electric shocks

LUA
Config.Job = {
    shockFailures = 2,
    shockMs = 4000,
}
SettingWhat it does
shockFailuresMistakes in a row before you get a shock. A switch latched in the right order sets the count back to zero, and so does the start of a new round. 0 turns shocks off.
shockMsHow long the shock lasts before the repair ends, in milliseconds.

When the limit is reached, the monitor reads OVERLOAD / INTERLOCK TRIPPING and then OVERLOAD / SUPPLY TRIPPED. The close-up camera ends, your character jolts and is thrown back from the cabinet, and smoke and sparks come out of the cabinet. The shock does not cost health.

After shockMs the repair ends. The cabinet is not restored. Open it again to start over, with new rounds and new orders.

Players within Config.Effects.smokeDistance (35 metres) see the smoke for Config.Effects.smokeMs (6.5 seconds). All four settings are on the Configuration page.


When a repair stops early

EventWhat happens
You press EscThe repair ends.
You get a shockThe repair ends after shockMs.
You move more than 1 metre beyond Config.Job.repairDistance, die or leave the main worldThe repair ends.
The time runs outA repair may take Config.Job.leaseMs (5 minutes). Each round you finish gives a fresh 5 minutes.
You leave the crewThe repair ends.

In every case the cabinet stays on the route. When it is opened again, it starts over from round 1.


When the cabinet is restored

When the door is closed the cabinet counts as restored:

  • Its map marker is removed and it counts towards the crew’s progress and your share of the payout. See Payouts.
  • When it was the last box of the route, the crew returns the van to the depot. See Work Van.
  • The cabinet tips are marked as learned for you and for a crewmate who was helping. See First-Time Tips.
  • The server hook Framework:onFinishMinigame runs. See Exports & Hooks.